Outils pour utilisateurs

Outils du site


materiel:hp:resolution_problemes_ilo

Résolution de problèmes iLO


RESTful API Error

Message d'erreur :

338-HPE RESTful API Error - Unable to communicate with iLO FW. BIOS
configuration resources may not be up-to-date.
Action: Restore Manufacturing Defaults in RBSU

Résolution : http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=c04423967

Procedure 4 Resolution 4: Resetting the HP RESTful API using the iLO SSH CLI

  1. Open an SSH connection with iLO, log in using an account with administrator privileges.
  2. At the CLI prompt, execute the command oemhp_clearRESTAPIstate.
    Note that this command might take a few seconds to complete.
  3. Restart the server.
materiel/hp/resolution_problemes_ilo.txt · Dernière modification : 2022/03/11 14:24 de 127.0.0.1